MainCatalogInstrument Engineering, Metrology, Information-Measuring Instruments and Systems All articles
Simulation of Nonstationary Processes in Pulse Tubular Xenon Lamps in Conditions of Return of Reflected Radiation into Plasma
Authors: Gradov V.M., Korobkov S.S., Terentyev Yu.I. | Published: 17.02.2019 |
Published in issue: #1(124)/2019 | |
DOI: 10.18698/0236-3933-2019-1-90-108 | |
Category: Informatics, Computer Engineering and Control | Chapter: Mathematical Modelling, Numerical Methods, and Program Complexes | |
Keywords: mathematical simulation, spectrum, flash lamp, radiation return, reflection coefficient, non-stationary plasma, absorption coefficient, radiation transfer, pumping band |
Simulation of Nonstationary Processes in Pulse Tubular Xenon Lamps in Conditions of Return of Reflected Radiation into Plasma
Authors: Gradov V.M., Korobkov S.S., Terentyev Yu.I. | Published: 17.02.2019 |
Published in issue: #1(124)/2019 | |
DOI: 10.18698/0236-3933-2019-1-90-108 | |
Category: Informatics, Computer Engineering and Control | Chapter: Mathematical Modelling, Numerical Methods, and Program Complexes | |
Keywords: mathematical simulation, spectrum, flash lamp, radiation return, reflection coefficient, non-stationary plasma, absorption coefficient, radiation transfer, pumping band |
Improved Algorithm for Mathematical Correction of the Zero Drift of the Zeeman Laser Gyro with Switching Longitudinal Mode of Generation
Authors: Kolbas Yu.Yu., Ivanov M.A. | Published: 17.04.2019 |
Published in issue: #2(125)/2019 | |
DOI: 10.18698/0236-3933-2019-2-91-103 | |
Category: Instrument Engineering, Metrology, Information-Measuring Instruments and Systems | Chapter: Navigation Instruments | |
Keywords: laser gyroscope, Zeeman effect, zero drift, temperature dependence, temperature sensor |
Universality of the Top-Level Software Structure for Noninvasive Spectrophotometric Diagnostic Devices
Authors: Tarasov A.P., Rogatkin D.A. | Published: 17.04.2019 |
Published in issue: #2(125)/2019 | |
DOI: 10.18698/0236-3933-2019-2-104-115 | |
Category: Instrument Engineering, Metrology, Information-Measuring Instruments and Systems | Chapter: Instruments, Systems, and Production for Medical Use | |
Keywords: functional diagnostics, spectrophotometric methods, software, graphic programming environment LabVIEW, databases |
Installation Device for Research of Electrical Characteristics of Integrated Elements of Feedthrough Phased Antenns Arrays
Authors: Rusov Yu.S., Ievlev D.I. | Published: 03.07.2019 |
Published in issue: #3(126)/2019 | |
DOI: 10.18698/0236-3933-2019-3-4-13 | |
Category: Instrument Engineering, Metrology, Information-Measuring Instruments and Systems | Chapter: Instruments and Measuring Methods | |
Keywords: mounting facility, integrated element, phased array antenna, feedthrough phased antenna array, electrical characteristics, measurement |
Noise Immunity Research of Multi-Frequency Information Transmission System with Code Division of Channels
Authors: Trubachev E.A., Senin A.I. | Published: 03.07.2019 |
Published in issue: #3(126)/2019 | |
DOI: 10.18698/0236-3933-2019-3-14-26 | |
Category: Instrument Engineering, Metrology, Information-Measuring Instruments and Systems | Chapter: Design and Instrument Engineering Technology and Electronic Equipment | |
Keywords: code division multiple access, Rayleigh fading, multi- frequency transmission system, noise immunity, error probability, intersymbol interference, simulation of random variables |
Ground-Based MIMO Microwave Cameras: Resolution and Stationary Object Imaging
Authors: Chapurskii V.V., Slukin G.P., Noniashvili M.I., Lesnikov G.A.  | Published: 06.07.2019 |
Published in issue: #3(126)/2019 | |
DOI: 10.18698/0236-3933-2019-3-77-94 | |
Category: Informatics, Computer Engineering and Control | Chapter: System Analysis, Control, and Information Processing | |
Keywords: multistatic microwave holography, MIMO microwave camera, microwave image, radar cross-section, stepped frequency modulation, generalized correlation integral in correlation processing, space-time processing |
Changing the Delay of the Analog-Digital Conversion in Reduce the Leakage Signal Effect
Authors: Kichigin A.A., Shakhtarin B.I. | Published: 06.07.2019 |
Published in issue: #3(126)/2019 | |
DOI: 10.18698/0236-3933-2019-3-95-102 | |
Category: Informatics, Computer Engineering and Control | Chapter: System Analysis, Control, and Information Processing | |
Keywords: short range radiolocation system, microwave module, linear frequency modulation, difference frequency signal, subsampling, leakage signal effect, microcontroller |
Fabrication of Tuning-Fork Gyroscope Resonator using Directed Chemical Etching of Fused Silica
Authors: Kuznetsov V.S., Maiorov D.V., Andreev P.A. | Published: 13.08.2019 |
Published in issue: #4(127)/2019 | |
DOI: 10.18698/0236-3933-2019-4-32-44 | |
Category: Instrument Engineering, Metrology, Information-Measuring Instruments and Systems | Chapter: Navigation Instruments | |
Keywords: fused silica, hydrofluoric acid, chemical etching, laser, structuring, gyroscope, resonator |
Effect of the Main Rotor and Other Helicopter Design Features on the Performance of Satellite Radionavigation System User Equipment Mounted on the Craft
Authors: Zubov N.E., Eshchenko A.A., Demin S.S., Maslennikova G.E., Ivanenko S.V. | Published: 03.09.2019 |
Published in issue: #4(127)/2019 | |
DOI: 10.18698/0236-3933-2019-4-71-83 | |
Category: Instrument Engineering, Metrology, Information-Measuring Instruments and Systems | Chapter: Instrumentation and Methods to Transform Images and Sound | |
Keywords: navigation, satellite radionavigation system, helicopter, main rotor, diffraction, antenna shielding, navigation accuracy, bit error rate |